Questions d'entretiens - Electrical engineer intern

114

Questions d'entretien pour Electrical Engineer Intern partagées par les candidats

Principales questions d'entretien

Trier: Pertinence|Populaires|Date
Imerys
On a demandé à Electrical Controls Engineer Intern...22 juin 2012

Do you know what a PLC is?

1 réponses

professional learning community

Graco

How did you get into EE?

1 réponses

Did a project in high school where I made a calculator and always loved inventing, building, and doing projects in my garage when younger Moins

Sensata Technologies

Asked me what MOSFETs were... and seemed surprised when I began explaining how they worked as opposed to what MOSFET stood for.

1 réponses

Metal Oxide Semiconductor Field-Effect Transistor

Raytheon Technologies

Example of technical project, hobbies relating to major, career plans.

1 réponses

I discussed previous research experience and relevant club activities.

Maxim Integrated

Open Circuit Gain of an op-amp

1 réponses

Infinite

Maxim Integrated

IV curve of a diode

1 réponses

described the proper graph of

Renault Group

What you can give the company as added value?

1 réponses

Can not, and should be a capital increase

Tektronix

A schematic shows a BJT in a common-collector configuration with the collector tied to ground, the base attached to a signal source, and the emitter connected through a resistor to -5V. In between the emitter and resistor is one end of a 75 Ohm transmission line. The other end is attached to a 75 Ohm resistor that terminates it to -5V. The signal source is a step with an initial voltage of -5V and a step voltage up to 0V. Determine the voltage at the emitter before and after the step. Then, draw the path of the loop current when the voltage transient has traveled halfway down the transmission line. Then, determine the voltage at the terminated end of the transmission line just before and just after the transient arrives. Determine how much power is reflected by the termination.

1 réponses

The emitter voltages are -5V and about -0.8V, respectively, creating a 4.2V transient wave. As the time when the transient is only halfway down the transmission line, the current loop is from ground, through the collector and emitter of the BJT, into the transmission line, and back to ground at the halfway point of the transmission line where the voltage transient is. The voltage at the terminated end of the line is -5V and -0.8V, respectively. There is no power reflected from the load. Moins

Norfolk Southern

How did you deal with adversity.

1 réponses

I used my related experience.

Graco

It takes 28 minutes for 5 machines to make five gizmos, how long does it take 100 machines to make 100 gizmos?

1 réponses

same amount of time

1 - 10 sur 114 Questions d'entretien

Consultez les questions posées en entretiens pour des emplois similaires

electrical internengineering internelectrical engineerengineering co op internpower systems engineerengineering internship